CVE Database
Synced from NVD, cross-referenced against CISA KEV and EPSS · ordered by last update
| CVE ID | Score | Description |
|---|---|---|
| 2mo ago | 7.1 | Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability in Scott Farrell wp Hosting Performance Check wp-hosting-performance-check allows Reflected XSS.This issue affects wp Hosting Performance Check: from n/a through <= 2.18.8. |
| 2mo ago | 7.2 | Deserialization of Untrusted Data vulnerability in kkarpieszuk WC Price History for Omnibus wc-price-history allows Object Injection.This issue affects WC Price History for Omnibus: from n/a through <= 2.1.4. |
| 2mo ago | 8.1 | Improper Control of Filename for Include/Require Statement in PHP Program ('PHP Remote File Inclusion') vulnerability in roninwp FAT Event Lite fat-event-lite allows PHP Local File Inclusion.This issue affects FAT Event Lite: from n/a through <= 1.1. |
| 2mo ago | 8.5 | Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection') vulnerability in Crispweb NC Wishlist for Woocommerce nc-wishlist-for-woocommerce allows SQL Injection.This issue affects NC Wishlist for Woocommerce: from n/a through <= 1.0.1. |
| 2mo ago | 7.1 | Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability in Opentracker Opentracker Analytics opentracker-analytics allows Reflected XSS.This issue affects Opentracker Analytics: from n/a through <= 1.3. |
| 2mo ago | 7.1 | Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability in tsinf TS Comfort DB ts-comfort-database allows Reflected XSS.This issue affects TS Comfort DB: from n/a through <= 2.0.7. |
| 2mo ago | 7.1 | Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability in P3JX Cf7Save Extension cf7save-extension allows Reflected XSS.This issue affects Cf7Save Extension: from n/a through <= 1. |
| 2mo ago | 7.1 | Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability in Mahesh Waghmare MG Parallax Slider mg-parallax-slider allows Reflected XSS.This issue affects MG Parallax Slider: from n/a through <= 1.0.. |
| 2mo ago | 7.1 | Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability in OTWthemes Widgetize Pages Light widgetize-pages-light allows Reflected XSS.This issue affects Widgetize Pages Light: from n/a through <= 3.0. |
| 2mo ago | 7.1 | Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability in Saiful Islam Product Table for WooCommerce woo-product-table allows Reflected XSS.This issue affects Product Table for WooCommerce: from n/a through <= 4.0.3. |
| 2mo ago | 7.1 | Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability in Tripetto WordPress form builder plugin for contact forms, surveys and quizzes – Tripetto tripetto allows Stored XSS.This issue affects WordPress form builder plugin for contact forms, surveys and quizzes – Tripetto: from n/a through <= 8.0.6. |
| Exploit 2mo ago | 8.2 | An attacker can arbitrarily craft malicious DDS Participants (or ROS 2 Nodes) with valid certificates to compromise and get full control of the attacked secure DDS databus system by exploiting vulnerable attributes in the configuration of PKCS#7 certificate’s validation. This is caused by a non-compliant implementation of permission document verification used by some DDS vendors. Specifically, an improper use of the OpenSSL PKCS7_verify function used to validate S/MIME signatures. |
| Exploit 2mo ago | 8.2 | An attacker can arbitrarily craft malicious DDS Participants (or ROS 2 Nodes) with valid certificates to compromise and get full control of the attacked secure DDS databus system by exploiting vulnerable attributes in the configuration of PKCS#7 certificate’s validation. This is caused by a non-compliant implementation of permission document verification used by some DDS vendors. Specifically, an improper use of the OpenSSL PKCS7_verify function used to validate S/MIME signatures. |
| Exploit 2mo ago | 8.2 | An attacker can arbitrarily craft malicious DDS Participants (or ROS 2 Nodes) with valid certificates to compromise and get full control of the attacked secure DDS databus system by exploiting vulnerable attributes in the configuration of PKCS#7 certificate’s validation. This is caused by a non-compliant implementation of permission document verification used by some DDS vendors. Specifically, an improper use of the OpenSSL PKCS7_verify function used to validate S/MIME signatures. |
| Exploit 2mo ago | 8.8 | A vulnerability classified as critical has been found in Tenda AC6 15.03.05.16. Affected is the function GetParentControlInfo of the file /goform/GetParentControlInfo. The manipulation of the argument src/mac leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. Other parameters might be affected as well. |
| Exploit 2mo ago | 8.8 | The SKT Page Builder plugin for WordPress is vulnerable to arbitrary file uploads due to a missing capability check on the 'addLibraryByArchive' function in all versions up to, and including, 4.6. This makes it possible for authenticated attackers, with subscriber-level access and above, to upload arbitrary files that make remote code execution possible. |
| Exploit 2mo ago | 8.6 | The linkID plugin for WordPress is vulnerable to unauthorized access of data due to a missing capability check when including the 'phpinfo' function in all versions up to, and including, 0.1.2. This makes it possible for unauthenticated attackers to read configuration settings and predefined variables on the site's server. The plugin does not need to be activated for the vulnerability to be exploited. |
| 2mo ago | 7.5 | The WP Database Backup – Unlimited Database & Files Backup by Backup for WP plugin for WordPress is vulnerable to Sensitive Information Exposure in all versions up to, and including, 7.3 via publicly accessible back-up files. This makes it possible for unauthenticated attackers to extract sensitive data including all information stored in the database. |
| Exploit 2mo ago | 7.3 | A vulnerability was found in code-projects Admission Management System 1.0. It has been declared as critical. This vulnerability affects unknown code of the file index.php of the component Login. The manipulation of the argument u_id leads to sql injection. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. |
| 2mo ago | 7.5 | The CGI script <redacted>.sh can be used to download any file on the filesystem. This issue affects Iocharger firmware for AC model chargers beforeversion 24120701. Likelihood: High, but credentials required. Impact: Critical – The script can be used to download any file on the filesystem, including sensitive files such as /etc/shadow, the CGI script source code or binaries and configuration files. CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N/S:P/AU:Y CVSS clarification. The attack can be executed over any network connection the station is listening to and serves the web interface (AV:N), and there are no additional security measure sin place that need to be circumvented (AC:L), the attack does not rely on preconditions (AT:N). The attack does require authentication, but the level of authentication is irrelevant (PR:L), it does not require user interaction (UI:N). The confidentiality of all files of the devicd can be compromised (VC:H/VI:N/VA:N). There is no impact on subsequent systems. (SC:N/SI:N/SA:N). While this device is an EV charger handing significant amounts of power, this attack in isolation does not have a safety impact. The attack can be automated (AU:Y). |
| Exploit 2mo ago | 7.2 | After gaining access to the firmware of a charging station, a file at <redacted> can be accessed to obtain default credentials that are the same across all Iocharger AC model EV chargers. This issue affects Iocharger firmware for AC models before firmware version 25010801. The issue is addressed by requiring a mandatory password change on first login, it is still recommended to change the password on older models. Likelihood: Moderate – The attacker will first have to abuse a code execution or file inclusion vulnerability (for example by using <redacted>.sh) to gain access to the <redacted>.json file, or obtain a firmware dump of the charging station or obtain the firmware via other channels. Impact: Critical – All chargers using Iocharger firmware for AC models started with the same initial password. For models with firmware version before 25010801 a password change was not mandatory. It is therefore very likely that this firmware password is still active on many chargers. These credentials could, once obtained, allow an attacker to log into many Iocharger charging station, and allow them to execute arbitrary commands via the System → Custom page. CVSS clarification: Any network interface serving the web ui is vulnerable (AV:N) and there are not additional security measures to circumvent (AC:L), nor does the attack require and existing preconditions (AT:N). The attack is authenticated, and requires high privileges (PR:H), there is no user interaction required (UI:N). The attack leads to a compromised of the confidentialy of the "super user" credentials of the device (VC:H/VI:N/VA:N), and can subsequently be used to full compromise and other devices (SC:H/SI:H/SA:H). Becuase this is an EV charger handing significant power, there is a potential safety impact (S:P). This attack can be automated (AU:Y). |
| 2mo ago | 8.8 | Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability allows OS Command Injection as root This issue affects Iocharger firmware for AC model chargers before version 24120701. Likelihood: High. However, the attacker will need a (low privilege) account to gain access to the action.exe CGI binary and upload the crafted firmware file, or convince a user with such access to upload it. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and deletefiles and services. CVSS clarification: Any network interface serving the web ui is vulnerable (AV:N) and there are not additional security measures to circumvent (AC:L), nor does the attack require and existing preconditions (AT:N). The attack is authenticated, but the level of authentication does not matter (PR:L), nor is any user interaction required (UI:N). The attack leads to a full compromised (VC:H/VI:H/VA:H), and compromised devices can be used to pivot into networks that should potentially not be accessible (SC:L/SI:L/SA:H). Becuase this is an EV charger handing significant power, there is a potential safety impact (S:P). This attack can be automated (AU:Y). |
| 2mo ago | 8.8 | Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability allows OS Command Injection as root This issue affects Iocharger firmware for AC model chargers before version 24120701. Likelihood: Moderate – It might be difficult for an attacker to identify the file structure of the <redated> directory, and then modify the backup to add a new CGI script in the correct directory. Furthermore, the attacker will need an account to restore the settings backup, or convince a user with such access to upload a modified backup file. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and deletefiles and services. CVSS clarification: Any network interface serving the web ui is vulnerable (AV:N) and there are not additional security measures to circumvent (AC:L), nor does the attack require and existing preconditions (AT:N). The attack is authenticated, but the level of authentication does not matter (PR:L), nor is any user interaction required (UI:N). The attack leads to a full compromised (VC:H/VI:H/VA:H), and compromised devices can be used to pivot into networks that should potentially not be accessible (SC:L/SI:L/SA:H). Becuase this is an EV charger handing significant power, there is a potential safety impact (S:P). This attack can be automated (AU:Y). |
| 2mo ago | 8.8 | Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability in Iocharger firmware for AC models allows OS Command Injection as root This issue affects all Iocharger AC EV charger models on a firmware version before 25010801. Likelihood: Moderate – The <redacted> binary does not seem to be used by the web interface, so it might be more difficult to find. It seems to be largely the same binary as used by the Iocharger Pedestal charging station, however. The attacker will also need a (low privilege) account to gain access to the <redacted> binary, or convince a user with such access to execute a crafted HTTP request. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete files and services. CVSS clarification: Any network interface serving the web ui is vulnerable (AV:N) and there are not additional security measures to circumvent (AC:L), nor does the attack require and existing preconditions (AT:N). The attack is authenticated, but the level of authentication does not matter (PR:L), nor is any user interaction required (UI:N). The attack leads to a full compromised (VC:H/VI:H/VA:H), and compromised devices can be used to pivot into networks that should potentially not be accessible (SC:L/SI:L/SA:H). Becuase this is an EV charger handing significant power, there is a potential safety impact (S:P). This attack can be automated (AU:Y). |
| 2mo ago | 8.8 | Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability allows OS Command Injection as root This issue affects Iocharger firmware for AC model chargers before version 24120701. Likelihood: Moderate – The <redacted> binary does not seem to be used by the web interface, so it might be more difficult to find. It seems to be largely the same binary as used by the Iocharger Pedestal charging station, however. The attacker will also need a (low privilege) account to gain access to the <redacted> binary, or convince a user with such access to execute a crafted HTTP request. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete files and services. CVSS clarification: Any network interface serving the web ui is vulnerable (AV:N) and there are not additional security measures to circumvent (AC:L), nor does the attack require and existing preconditions (AT:N). The attack is authenticated, but the level of authentication does not matter (PR:L), nor is any user interaction required (UI:N). The attack leads to a full compromised (VC:H/VI:H/VA:H), and compromised devices can be used to pivot into networks that should potentially not be accessible (SC:L/SI:L/SA:H). Becuase this is an EV charger handing significant power, there is a potential safety impact (S:P). This attack can be automated (AU:Y). |
| 2mo ago | 8.8 | Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability allows OS Command Injection as root This issue affects Iocharger firmware for AC model chargers before version 24120701 Likelihood: Moderate – The <redacted> binary does not seem to be used by the web interface, so it might be more difficult to find. It seems to be largely the same binary as used by the Iocharger Pedestal charging station, however. The attacker will also need a (low privilege) account to gain access to the <redacted> binary, or convince a user with such access to execute a crafted HTTP request. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete files and services. |
| Exploit 2mo ago | 8.8 | Authenticated command injection in the filename of a <redacted>.exe request leads to remote code execution as the root user. This issue affects Iocharger firmware for AC models before version 24120701. Likelihood: Moderate – This action is not a common place for command injection vulnerabilities to occur. Thus, an attacker will likely only be able to find this vulnerability by reverse-engineering the firmware or trying it on all <redacted> fields. The attacker will also need a (low privilege) account to gain access to the <redacted> binary, or convince a user with such access to execute a payload. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete files and services. CVSS clarification: This attack can be performed over any network conenction serving the web interfacr (AV:N), and there are not additional mitigating measures that need to be circumvented (AC:L) or other prerequisites (AT:N). The attack does require privileges, but the level does not matter (PR:L), there is no user interaction required (UI:N). The attack leeds to a full compromised of the charger (VC:H/VI:H/VA:H) and a compromised charger can be used to "pivot" to networks that should normally not be reachable (SC:L/SI:L/SA:H). Because this is an EV chargers with significant pwoer, there is a potential safety imp0act (S:P). THis attack can be automated (AU:Y). |
| Exploit 2mo ago | 8.8 | Command injection in the <redacted> parameter of a <redacted>.exe request leads to remote code execution as the root user. This issue affects Iocharger firmware for AC models before version 24120701. Likelihood: Moderate – This action is not a common place for command injection vulnerabilities to occur. Thus, an attacker will likely only be able to find this vulnerability by reverse-engineering the firmware or trying it on all <redacted> fields. The attacker will also need a (low privilege) account to gain access to the <redacted> binary, or convince a user with such access to execute a payload. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete files and services. CVSS clarification. The attack can be executed over any network connection the station is listening to and serves the web interface (AV:N), and there are no additional security measure sin place that need to be circumvented (AC:L), the attack does not rely on preconditions (AT:N). The attack does require authentication, but the level of authentication is irrelevant (PR:L), it does not require user interaction (UI:N). If is a full system compromise, potentially fully compromising confidentiality, integrity and availability of the devicer (VC:H/VI:H/VA:H). A compromised charger can be used to "pivot" onto networks that should otherwise be closed, cause a low confidentiality and interity impact on subsequent systems. (SC:L/SI:L/SA:H). Because this device is an EV charger handing significant amounts of power, we suspect this vulnerability can have a safety impact (S:P). The attack can be automated (AU:Y). |
| Exploit 2mo ago | 7.2 | A post-authentication format string vulnerability in SonicOS management allows a remote attacker to crash a firewall and potentially leads to code execution. |
| Exploit 2mo ago | 7.2 | A post-authentication stack-based buffer overflow vulnerability in SonicOS management allows a remote attacker to crash a firewall and potentially leads to code execution. |