AUGUST 4, 2026
Live Feed
Back to database
Case File

CVE-2024-43659

HIGH · CVSS 7.2 EPSS 0.85% Public Exploit

Source: NVD + CISA KEV + EPSS (historical backfill) · Published 2025-01-09 · Last synced 2026-08-04

CyberRota Analysis

This is a high severity vulnerability with a CVSS score of 7.2. Public exploit code or proof-of-concept references have been detected in its references.

Public Exploit Signal

A public exploit, PoC, GitHub repository or Metasploit reference was detected for this CVE.

Detected Signals
code execution

Note: these links are listed for security research and verification purposes only.

CVE
CVE-2024-43659
Severity
HIGH
CVSS
7.2
EPSS
0.85%

Original NVD Description

After gaining access to the firmware of a charging station, a file at <redacted> can be accessed to obtain default credentials that are the same across all Iocharger AC model EV chargers. This issue affects Iocharger firmware for AC models before firmware version 25010801. The issue is addressed by requiring a mandatory password change on first login, it is still recommended to change the password on older models. Likelihood: Moderate – The attacker will first have to abuse a code execution or file inclusion vulnerability (for example by using <redacted>.sh) to gain access to the <redacted>.json file, or obtain a firmware dump of the charging station or obtain the firmware via other channels. Impact: Critical – All chargers using Iocharger firmware for AC models started with the same initial password. For models with firmware version before 25010801 a password change was not mandatory. It is therefore very likely that this firmware password is still active on many chargers. These credentials could, once obtained, allow an attacker to log into many Iocharger charging station, and allow them to execute arbitrary commands via the System → Custom page. CVSS clarification: Any network interface serving the web ui is vulnerable (AV:N) and there are not additional security measures to circumvent (AC:L), nor does the attack require and existing preconditions (AT:N). The attack is authenticated, and requires high privileges (PR:H), there is no user interaction required (UI:N). The attack leads to a compromised of the confidentialy of the "super user" credentials of the device (VC:H/VI:N/VA:N), and can subsequently be used to full compromise and other devices (SC:H/SI:H/SA:H). Becuase this is an EV charger handing significant power, there is a potential safety impact (S:P). This attack can be automated (AU:Y).