CyberRota Analysis
AI-GeneratedThe BioStar Temperature Monitor Utility version 1.2.1806.2200 is vulnerable due to a write-what-where condition in the IOCTL Handler, specifically within the sub_1105C function of the BS_HWMIO64_W10.sys file. This vulnerability allows local attackers to manipulate memory addresses, potentially leading to arbitrary code execution. Organizations using this utility should prioritize patching or mitigating this vulnerability, as it poses a significant risk given its public disclosure and high severity rating.
Public Exploit Signal
A public exploit, PoC, GitHub repository or Metasploit reference was detected for this CVE.
Note: these links are listed for security research and verification purposes only.
Original NVD Description
A security vulnerability has been detected in BioStar Temperature Monitor Utility 1.2.1806.2200. Affected by this vulnerability is the function sub_1105C of the file BS_HWMIO64_W10.sys of the component IOCTL Handler. Such manipulation of the argument PhysicalAddress leads to write-what-where condition. The attack needs to be performed locally. The exploit has been disclosed publicly and may be used. The vendor was contacted early about this disclosure but did not respond in any way.