AI-Generated

The vulnerability affects the Linux kernel's power supply management, specifically in the charger manager component, where improper handling of regulator references can lead to use-after-free conditions. This flaw allows a concurrent write to the sysfs attribute to dereference freed handles, potentially leading to system instability or arbitrary code execution. Organizations using Linux-based systems, particularly those managing power supply components, should prioritize addressing this vulnerability to mitigate risks associated with system exploitation.

CVE
CVE-2026-89472
Severity
HIGH
CVSS
7.8
EPSS
0.16%
Windows Linux

Original NVD Description

In the Linux kernel, the following vulnerability has been resolved: power: supply: charger-manager: register regulators before exposing sysfs charger_manager_remove() and the err_reg_extcon probe error path free each charger regulator with regulator_put() before tearing down the power_supply sysfs entries (power_supply_unregister()). charger_manager_remove() also calls try_charger_enable(cm, false) after the regulator_put() loop. A concurrent write to a charger's externally_control sysfs attribute that lands between regulator_put() and power_supply_unregister() can run charger_externally_control_store() and call try_charger_enable(), which, when charging is enabled, dereferences the already-freed consumer handle. When charging is enabled, try_charger_enable(cm, false) in .remove() also dereferences the freed handles directly. Both leave use-after-free windows. Symmetrically, probe registers the sysfs entries (power_supply_register) before acquiring the regulators (regulator_get, inside charger_manager_register_extcon), so userspace can reach externally_control before the regulators are available. Split charger_manager_register_extcon() on the sync/async boundary: charger_manager_get_regulators() (regulator_get only, no async producer) now runs before power_supply_register() so sysfs is not live before regulators are available, and charger_manager_register_extcon() keeps only the extcon notifier/work setup, still after power_supply_register() so a power_supply_register() failure cannot reach extcon setup. This keeps the sysfs setup/teardown ordering symmetric without introducing an asynchronous producer on the earlier probe-error path. Move power_supply_unregister() and try_charger_enable(cm, false) ahead of the regulator_put() loop on both teardown paths, and adjust err_reg_extcon (power_supply_unregister() then fall through err_regulator for regulator_put(); get_regulators self-rolls back on its own failure). This does not address the separate extcon-notifier-driven deref of the same handles, which needs its own synchronization design. Found by an in-house static analysis tool.