CyberRota Analysis
This is a critical severity vulnerability with a CVSS score of 9.8. It affects Linux. Public exploit code or proof-of-concept references have been detected in its references. It may be remotely exploitable. Exploitation may require the attacker to be authenticated.
Public Exploit Signal
A public exploit, PoC, GitHub repository or Metasploit reference was detected for this CVE.
Note: these links are listed for security research and verification purposes only.
Original NVD Description
Nefteprodukttekhnika BUK TS-G Gas Station Automation System 2.9.1 through 2.10.2 on Linux contains an Improper Authentication vulnerability (CWE-287) in the system configuration module. The /php/ajax-login.php endpoint returns userid=1 (administrator) in response to any HTTP POST request that supplies arbitrary credentials (e.g., action=dologin&login=<any_value>&pwd=<any_value>), and subsequent privileged endpoints under /php/ajax-main.php and /modules/* do not validate a server-side session. A remote unauthenticated attacker can invoke any administrative action exposed by the configuration module, including reading and modifying user rules, fuel tank gauges, fuel dispensers, relays, cash registers, bank terminals, fuel cards, price and customer displays, cash collection, and pricing rules.