SEPTEMBER 8, 2026
Live Feed
Vulnerability Register

CVE Database

Synced from NVD, cross-referenced against CISA KEV and EPSS · ordered by last update

35,593 records on file
Page 661 of 1,187
CVE ID Score Description
1mo ago
9.8

Input passed to the Pdf() function is shell escaped and passed to child_process.exec() during PDF rendering. However, the shell escape does not properly encode all special characters, namely, semicolon and curly braces. This can be abused to achieve command execution. This problem affects nodepdf 1.3.0.

Exploit 1mo ago
9.8

Honeywell Experion PKS Safety Manager (SM and FSC) through 2022-05-06 has Insufficient Verification of Data Authenticity. According to FSCT-2022-0053, there is a Honeywell Experion PKS Safety Manager insufficient logic security controls issue. The affected components are characterized as: Honeywell FSC runtime (FSC-CPU, QPP), Honeywell Safety Builder. The potential impact is: Remote Code Execution, Denial of Service. The Honeywell Experion PKS Safety Manager family of safety controllers utilize the unauthenticated Safety Builder protocol (FSCT-2022-0051) for engineering purposes, including downloading projects and control logic to the controller. Control logic is downloaded to the controller on a block-by-block basis. The logic that is downloaded consists of FLD code compiled to native machine code for the CPU module (which applies to both the Safety Manager and FSC families). Since this logic does not seem to be cryptographically authenticated, it allows an attacker capable of triggering a logic download to execute arbitrary machine code on the controller's CPU module in the context of the runtime. While the researchers could not verify this in detail, the researchers believe that the microprocessor underpinning the FSC and Safety Manager CPU modules is incapable of offering memory protection or privilege separation capabilities which would give an attacker full control of the CPU module. There is no authentication on control logic downloaded to the controller. Memory protection and privilege separation capabilities for the runtime are possibly lacking. The researchers confirmed the issues in question on Safety Manager R145.1 and R152.2 but suspect the issue affects all FSC and SM controllers and associated Safety Builder versions regardless of software or firmware revision. An attacker who can communicate with a Safety Manager controller via the Safety Builder protocol can execute arbitrary code without restrictions on the CPU module, allowing for covert manipulation of control operations and implanting capabilities similar to the TRITON malware (MITRE ATT&CK software ID S1009). A mitigating factor with regards to some, but not all, of the above functionality is that these require the Safety Manager physical keyswitch to be in the right position.

1mo ago
10

Buffer copy without checking size of input ('Classic Buffer Overflow') vulnerability in cgi component in Synology Media Server before 1.8.1-2876 allows remote attackers to execute arbitrary code via unspecified vectors.

1mo ago
9.9

An issue was discovered in Veritas NetBackup 8.1.x through 8.1.2, 8.2, 8.3.x through 8.3.0.2, 9.x through 9.0.0.1, and 9.1.x through 9.1.0.1 (and related NetBackup products). An attacker with authenticated access to a NetBackup Client could remotely execute arbitrary commands on a NetBackup Primary server (in specific notify conditions).

1mo ago
9.6

An issue was discovered in Veritas NetBackup 8.1.x through 8.1.2, 8.2, 8.3.x through 8.3.0.2, 9.x through 9.0.0.1, and 9.1.x through 9.1.0.1 (and related NetBackup products). An attacker with authenticated access to a NetBackup Client could remotely write arbitrary files to arbitrary locations from any Client to any other Client via a Primary server.

1mo ago
9.3

Out of bounds read in compositing in Google Chrome prior to 102.0.5005.115 allowed a remote attacker who had compromised the renderer process to potentially perform a sandbox escape via a crafted HTML page.

1mo ago
9.6

Use after free in Indexed DB in Google Chrome prior to 102.0.5005.61 allowed a remote attacker to potentially perform a sandbox escape via a crafted HTML page.

1mo ago
9

In Veritas NetBackup, the NetBackup Client allows arbitrary command execution from any remote host that has access to a valid host-id NetBackup certificate/private key from the same domain. The affects 9.0.x through 9.0.0.1 and 9.1.x through 9.1.0.1.

1mo ago
9.9

In Veritas NetBackup OpsCenter, under specific conditions, an authenticated remote attacker may be able to create or modify OpsCenter user accounts. This affects 8.x through 8.3.0.2, 9.x through 9.0.0.1, 9.1.x through 9.1.0.1, and 10.

Exploit 1mo ago
9.8

In Veritas NetBackup OpsCenter, an unauthenticated remote attacker may compromise the host by exploiting an incorrectly patched vulnerability. This affects 8.x through 8.3.0.2, 9.x through 9.0.0.1, 9.1.x through 9.1.0.1, and 10.

1mo ago
9.8

In Veritas NetBackup OpsCenter, an unauthenticated remote attacker may be able to perform remote command execution through a Java classloader manipulation. This affects 8.x through 8.3.0.2, 9.x through 9.0.0.1, 9.1.x through 9.1.0.1, and 10.

1mo ago
9.3

In Veritas NetBackup OpsCenter, an attacker with local access to a NetBackup OpsCenter server could potentially escalate their privileges. This affects 8.x through 8.3.0.2, 9.x through 9.0.0.1, 9.1.x through 9.1.0.1, and 10.

1mo ago
9.8

OX App Suite through 7.10.6 allows OS Command Injection via a serialized Java class to the Documentconverter API.

1mo ago
9.8

OX App Suite through 7.10.6 allows OS Command Injection via Documentconverter (e.g., through an email attachment).

1mo ago
10

An authentication bypass vulnerability in Skyhigh SWG in main releases 10.x prior to 10.2.12, 9.x prior to 9.2.23, 8.x prior to 8.2.28, and controlled release 11.x prior to 11.2.1 allows a remote attacker to bypass authentication into the administration User Interface. This is possible because of SWG incorrectly whitelisting authentication bypass methods and using a weak crypto password. This can lead to the attacker logging into the SWG admin interface, without valid credentials, as the super user with complete control over the SWG.

1mo ago
9.1

HashiCorp Vault Enterprise 1.7.0 through 1.9.7, 1.10.4, and 1.11.0 clusters using Integrated Storage expose an unauthenticated API endpoint that could be abused to override the voter status of a node within a Vault HA cluster, introducing potential for future data loss or catastrophic failure. Fixed in Vault Enterprise 1.9.8, 1.10.5, and 1.11.1.

1mo ago
9.8

The Motorola ACE1000 RTU through 2022-05-02 uses ECB encryption unsafely. It can communicate with an XRT LAN-to-radio gateway by means of an embedded client. Credentials for accessing this gateway are stored after being encrypted with the Tiny Encryption Algorithm (TEA) in ECB mode using a hardcoded key. Similarly, the ACE1000 RTU can route MDLC traffic over Extended Command and Management Protocol (XCMP) and Network Layer (XNL) networks via the MDLC driver. Authentication to the XNL port is protected by TEA in ECB mode using a hardcoded key.

1mo ago
9.8

The Motorola ACE1000 RTU through 2022-05-02 ships with a hardcoded SSH private key and initialization scripts (such as /etc/init.d/sshd_service) only generate a new key if no private-key file exists. Thus, this hardcoded key is likely to be used by default.

1mo ago
9.8

The Motorola ACE1000 RTU through 2022-05-02 has default credentials. It exposes an SSH interface on port 22/TCP. This interface is used for remote maintenance and for SFTP file-transfer operations that are part of engineering software functionality. Access to this interface is controlled by 5 preconfigured accounts (root, abuilder, acelogin, cappl, ace), all of which come with default credentials. Although the ACE1000 documentation mentions the root, abuilder and acelogin accounts and instructs users to change the default credentials, the cappl and ace accounts remain undocumented and thus are unlikely to have their credentials changed.

1mo ago
9.8

The Omron SYSMAC Cx product family PLCs (CS series, CJ series, and CP series) through 2022-05-18 lack cryptographic authentication. They utilize the Omron FINS (9600/TCP) protocol for engineering purposes, including downloading projects and control logic to the PLC. This protocol has authentication flaws as reported in FSCT-2022-0057. Control logic is downloaded to PLC volatile memory using the FINS Program Area Read and Program Area Write commands or to non-volatile memory using other commands from where it can be loaded into volatile memory for execution. The logic that is loaded into and executed from the user program area exists in compiled object code form. Upon execution, these object codes are first passed to a dedicated ASIC that determines whether the object code is to be executed by the ASIC or the microprocessor. In the former case, the object code is interpreted by the ASIC whereas in the latter case the object code is passed to the microprocessor for object code interpretation by a ROM interpreter. In the abnormal case where the object code cannot be handled by either, an abnormal condition is triggered and the PLC is halted. The logic that is downloaded to the PLC does not seem to be cryptographically authenticated, thus allowing an attacker to manipulate transmitted object code to the PLC and either execute arbitrary object code commands on the ASIC or on the microprocessor interpreter.

Exploit 1mo ago
9.8

The Omron SYSMAC Nx product family PLCs (NJ series, NY series, NX series, and PMAC series) through 2022-005-18 lack cryptographic authentication. These PLCs are programmed using the SYMAC Studio engineering software (which compiles IEC 61131-3 conformant POU code to native machine code for execution by the PLC's runtime). The resulting machine code is executed by a runtime, typically controlled by a real-time operating system. The logic that is downloaded to the PLC does not seem to be cryptographically authenticated, allowing an attacker to manipulate transmitted object code to the PLC and execute arbitrary machine code on the processor of the PLC's CPU module in the context of the runtime. In the case of at least the NJ series, an RTOS and hardware combination is used that would potentially allow for memory protection and privilege separation and thus limit the impact of code execution. However, it was not confirmed whether these sufficiently segment the runtime from the rest of the RTOS.

1mo ago
9.8

The Motorola MDLC protocol through 2022-05-02 mishandles message integrity. It supports three security modes: Plain, Legacy Encryption, and New Encryption. In Legacy Encryption mode, traffic is encrypted via the Tiny Encryption Algorithm (TEA) block-cipher in ECB mode. This mode of operation does not offer message integrity and offers reduced confidentiality above the block level, as demonstrated by an ECB Penguin attack against any block ciphers.

1mo ago
9.8

JTEKT TOYOPUC PLCs through 2022-04-29 do not ensure data integrity. They utilize the unauthenticated CMPLink/TCP protocol for engineering purposes, including downloading projects and control logic to the PLC. Control logic is downloaded to the PLC on a block-by-block basis with a given memory address and a blob of machine code. The logic that is downloaded to the PLC is not cryptographically authenticated, allowing an attacker to execute arbitrary machine code on the PLC's CPU module in the context of the runtime. In the case of the PC10G-CPU, and likely for other CPU modules of the TOYOPUC family, a processor without MPU or MMU is used and this no memory protection or privilege-separation capabilities are available, giving an attacker full control over the CPU.

1mo ago
9.8

The Bently Nevada 3700 series of condition monitoring equipment through 2022-04-29 has a maintenance interface on port 4001/TCP with undocumented, hardcoded credentials. An attacker capable of connecting to this interface can thus trivially take over its functionality.

1mo ago
9.1

Bently Nevada condition monitoring equipment through 2022-04-29 mishandles authentication. It utilizes the TDI command and data protocols (60005/TCP, 60007/TCP) for communications between the monitoring controller and System 1 and/or Bently Nevada Monitor Configuration (BNMC) software. These protocols provide configuration management and historical data related functionality. Neither protocol has any authentication features, allowing any attacker capable of communicating with the ports in question to invoke (a subset of) desired functionality.

1mo ago
9.1

JTEKT TOYOPUC PLCs through 2022-04-29 mishandle authentication. They utilize the CMPLink/TCP protocol (configurable on ports 1024-65534 on either TCP or UDP) for a wide variety of engineering purposes such as starting and stopping the PLC, downloading and uploading projects, and changing configuration settings. This protocol does not have any authentication features, allowing any attacker capable of communicating with the port in question to invoke (a subset of) desired functionality.

1mo ago
9.8

In Zoho ManageEngine SupportCenter Plus before 11023, V3 API requests are vulnerable to authentication bypass. (An API request may, in effect, be executed with the credentials of a user who authenticated in the past.)

Exploit 1mo ago
9.8

Orange Station 1.0 was discovered to contain a SQL injection vulnerability via the username parameter.

Exploit 1mo ago
9.8

Fruits Bazar v1.0 was discovered to contain a SQL injection vulnerability via the recover_email parameter at user_password_recover.php.

Exploit 1mo ago
9.8

A vulnerability in adm.cgi of WAVLINK WN535 G3 M35G3R.V5030.180927 allows attackers to execute arbitrary code via a crafted POST request.